Maintenance

Removing the HUD from the Divator Full Face
Mask
1.
Use a finger to tilt the Head-Up-Display away from the visor frame.
2.
Carefully turn the Head-Up-Display until it snaps off the visor frame.

Cleaning

1.
Rinse all parts of the HUD with clean freshwater. If necessary use a mild
detergent.
2.
Allow to air dry until completely dry.

Periodic inspection

Periodic inspection should be performed once a year or when there is a suspi-
cion that the HUD does not function properly.
1.
On a protocol to be filed, make a note of the HUD identity number. The
identity number consists of year (2 digits), week (2 digits) and a serial
number.
2.
Follow the instructions in the section "Pre-dive check of warning device"
and perform a full warning device function test.
3.
Do a full visual inspection of the HUD.
If there are any signs of damage or if the HUD does not behave according to
this manual return the HUD to the manufacturer for control and repair.