7

CHECKS AND MAINTENANCE

7.1
Check that the cylinder is fully charged and that the anti-tamper seal is unbroken.
7.2
Visual check
Check that there has been no mechanical or chemical damage to the following parts:
Bag, straps and quick-start ring.
l
Air hose, hose couplings and O-rings. Hoses that have lost their flexibility must be
l
replaced.
Outer and inner hood, neck seal and inner mask, including the two snap rings that
l
secure the inner mask and valve.
Sparingly apply talcum powder 460 190 130 (or another talcum powder) to the
l
neck seal at least once a year or as necessary.
Cylinder valve, regulator and pressure gauge.
l
Check that the cylinder has been tested according to national standards.
l
Function check
In addition to the visual check described above, Spiroscape must be tested to ensure
that the apparatus is working properly. To check this, start Spiroscape in exactly the
same way as for normal use and check that the duration time is at least 15 minutes
and 20 minutes at the maximum. During the test, the pressure gauge indicator should
drop from full to empty.
When checking and testing is complete, charge the cylinder as described in chapter 5
and fit the anti-tamper seal as described in chapter 6.
NOTE: IF THERE ARE ANY SIGNS OF DAMAGE OR IF THE APPARATUS DOES NOT WORK PROPERLY, SEND THE APPARATUS
FOR SERVICING OR REPLACE ANY PARTS THAT NEED TO BE REPLACED.
Keep a record of the checking and testing of the Spiroscape. State the date and the
serial number stamped on the cylinder valve.