Prerequisites for installation

Prerequisites for installation

For exhaust air operation

WARNING
Risk of suffocation/explosion!
■ Never attach the exhaust hood to a
ventilation shaft, chimney or smo-
kestack! The air being extracted must
not travel through a channel in which
warm air circulates. The extracted air
may only be released to the outside
through a separate air channel inten-
ded exclusively for the exhaust hood.
Before installing the exhaust hood, the cei-
ling break and, if necessary, the adjacent wall
break (core drilling) must be completed by a
specialist company.
The exhaust vent on the exhaust hood is
connected to the ceiling opening. Use an
exhaust air hose (not included in the package
contents).
– The length of the exhaust hose is deter-
mined by the thickness of the ceiling and
the distance between the ceiling and the
upper edge of the exhaust hood. Shorten
the exhaust hose to the required length to
avoid power loss.
– If the exhaust air hose passes through an
exterior wall, the air outlet on the outside
must have a cover with self-opening slits
(not included in the package contents).
To keep subsequent energy usage as low as
possible, we recommend
– placing the exhaust air channels as straight
as possible and avoiding any sharp angles
(curves or bends are preferable). Each
bend increases energy usage.
– not reducing the cross-section of the fan
connector. The wider the diameter of the
exhaust air hose and the smoother its inte-
rior surface, the better the extraction func-
tion will be.
– selecting a ventilation conduit with exterior
shutters that can open completely during
use.

Connection for power supply

WARNING
Risk of electric shock!
■ The mains plug must be as accessib-
le as possible during use, i.e. the plug
must be accessible even after the
exhaust hood has been installed.
■ If the mains plug is no longer acces-
sible after installation, an all-pole dis-
connecting device complying with
over-voltage category III must be
connected to the house wiring with a
contact gap of at least 3 mm; this in-
cludes fuses, circuit breakers and con-
tactors.
■ Electrical installation may be perfor-
med only by a certifi ed specialist. If
an additional socket is required, have
an electrician perform the installati-
on.
■ Do not connect to a power strip, mul-
tiple socket outlet, timer or to a sepa-
rate remote-controlled system for dis-
tance monitoring and control.
To ensure that the exhaust hood will perform
optimally and that no obtrusive cabling is visib-
le, plan the connection for power supply ca-
refully before installation: The exhaust hood
must be placed over the centre of the cooking
zone.