Preparations for assembly

Preparations for assembly

For exhaust air operation

WARNING
Risk of suffocation/explosion!
The air in the room where the exhaust
hood is operating is extracted by fan and
released outside. If, in this room, a fi re-
place requiring indoor air – such as a gas
fi re or other fuel-based heating system –
is also in use, the oxygen that is necessary
for combustion may also be extracted.
This can result in the fl ame being extin-
guished and gas being released or the
room becoming saturated with exhaust
fumes.
Never attach the exhaust hood to a
ventilation shaft, chimney or smoke-
stack! The air being extracted must not
travel through a channel in which warm
air circulates. The extracted air may
only be released to the outside through
a separate air channel intended exclu-
sively for the exhaust hood.
NOTICE
Risk of damage to property!
Improper handling of the appliance
may result in damage to property.
We recommend having a specialist car-
ry out all preparations.
Before you can begin assembly, all of the fol-
lowing conditions must be met:
– There must be a wall or ceiling break of at
least 15.5 cm in diameter.
– If the exhaust air hose passes through an ex-
terior wall, the air outlet on the outside must
have a cover with self-opening slits (not in-
cluded in the package contents).
To keep subsequent energy usage as low as
possible, we recommend
– placing the exhaust air channels as straight
as possible and avoiding any sharp angles
(curves or bends are preferable). Each bend
increases energy usage.
– not reducing the cross-section of the fan con-
nector. The wider the diameter of the exhaust
air hose and the smoother its interior surface,
the better the extraction function will be.
– selecting a ventilation conduit with exterior
shutters that can open completely during
use.

Connection for power supply

WARNING
Risk of electric shock!
Touching live parts may result in severe
injury or death.
The mains plug must be as accessi-
ble as possible during use, i.e. the plug
must be accessible even after the ex-
haust hood has been installed.
If the mains plug is no longer accessi-
ble after installation, an all-poles dis-
connecting device complying with
overvoltage category III must be con-
nected to the house wiring with a con-
tact gap of at least 3 mm; this includes
fuses, circuit breakers and contactors.
Electrical installation may be per-
formed only by a certifi ed specialist. If
an additional socket is required, have
an electrician perform the installation.
Do not connect to a multiple socket
outlet, power strip, timer or to a sepa-
rate remote-controlled system for dis-
tance monitoring and control.
To ensure that the exhaust hood will perform
optimally and that no obtrusive cabling is visi-
ble, plan the connection for power supply care-
fully before installation. The exhaust hood must
be placed over the centre of the cooking zone.