Figure 103. Installing the right ear handle for Rear Accessed configuration
Next steps
1.
Install the expansion card riser
2.
Install the air
shrouds.
3. Follow the procedure listed in the
Removing the status LED control panel for Front Accessed
configuration
Prerequisites
NOTE:
For Front Accessed configuration, the status LED control panel is on the rear of the system.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shrouds.
4.
Remove the processor and heat sink
5.
Remove the expansion card riser
NOTE:
If required, remove the backplane power and signal cables.
Steps
1. Disconnect the status LED control panel cable from the system board connector.
NOTE:
Observe the routing of the cable as you remove it from the system.
2. Using the Torx 8 screwdriver, remove the screws that secure the status LED control panel assembly to the system.
3. Hold the left status LED control panel assembly and remove the control panel along with the cable from the system.
NOTE:
Die Zahlen auf dem Bild zeigen nicht die genauen Schritte. Die Zahlen dienen der Darstellung der Sequenz.
104
Installieren und Entfernen von Systemkomponenten
1.
After working inside your
Safety
instructions.
Before working inside your
module.
1.
system.
system.