Herunterladen Inhalt Inhalt Diese Seite drucken

Systemdiagnose Und Anzeigecodes - Dell EMC PowerEdge XR11 Installations- Und Servicehandbuch

Vorschau ausblenden Andere Handbücher für EMC PowerEdge XR11:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

In diesem Abschnitt werden die Diagnoseanzeigen auf der Frontblende des Systems beschrieben, die den Systemstatus beim
Systemstart wiedergeben.
Themen:
Status LED indicators
System health and system ID indicator codes
iDRAC Direct-LED-Anzeigecodes
NIC-Anzeigecodes
Netzteil-Anzeigecodes
Drive indicator codes
Verwenden der Systemdiagnose
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Figure 113. Status LED indicators
Table 31. Status LED indicators and descriptions
Icon
Description
Drive indicator
Temperature
indicator
Electrical
indicator

Systemdiagnose und Anzeigecodes

Condition
The indicator turns solid amber if
there is a drive error.
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
The indicator turns solid amber
if the system experiences an
Corrective action
● Check the System Event Log to determine if the
drive has an error.
● Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
● If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● System cover, air shrouds, or back filler bracket
has been removed.
● Ambient temperature is too high.
● External airflow is obstructed.
If the problem persists, see the
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
Systemdiagnose und Anzeigecodes
8
Getting help
section.
115

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

E72s

Inhaltsverzeichnis