Herunterladen Inhalt Inhalt Diese Seite drucken

LIVSANE FDIR-V22 Gebrauchsanweisung Seite 8

Kontaktloses infrarot-thermometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
Troubles or error
Troubles or error
message
message
14. Specifications
14. Specifications
Device name
Device name
Model
Model
Measurement mode
Measurement mode
Measurement site
Measurement site
Measuring distance
Measuring distance
Power supply
Power supply
Measuring range
Measuring range
Measuring accuracy
Measuring accuracy
Clinical repeatability
Clinical repeatability
Resolution of display
Resolution of display
Operation condition temperature
Operation condition temperature
Transport / Storage condition
Transport / Storage condition
temperature
temperature
Size
Size
Weight
Weight
High body temperature hint
High body temperature hint
Grade of waterproof
Grade of waterproof
Electric shock
Electric shock
Applied part
Applied part
Mode of operation
Mode of operation
Software Version
Software Version
*The above specifications are subject to change without prior notice.
*The above specifications are subject to change without prior notice.
Note: ASTM laboratory accuracy requirements in the display range for 36 to 39 °C (96.8 to 102.2 °F) for
Note: ASTM laboratory accuracy requirements in the display range for 36 to 39 °C (96.8 to 102.2 °F) for
this thermometer is ±0,2 °C (±0.4 °), whereas for mercury-in-glass thermometers, the requirement per
this thermometer is ±0,2 °C (±0.4 °), whereas for mercury-in-glass thermometers, the requirement per
ASTM standards E 667 – 86 is ±0,1 °C (±0.2 °F).
ASTM standards E 667 – 86 is ±0,1 °C (±0.2 °F).
V22 BOOK.indb 8
V22 BOOK.indb 8
Checklists or situation
Checklists or situation
Too low battery. You can't use it any further.
Too low battery. You can't use it any further.
Non-Contact Infrared Thermometer
Non-Contact Infrared Thermometer
FDIR-V22
FDIR-V22
Forehead and object temperature measurement modes
Forehead and object temperature measurement modes
Forehead temperature
Forehead temperature
1 – 6 cm (0.4 in – 2.5 in)
1 – 6 cm (0.4 in – 2.5 in)
d.c.3 V, 2x1.5 V AAA batteries
d.c.3 V, 2x1.5 V AAA batteries
For forehead temperature: 32,0 – 42,9 °C (89.6 °F – 109.2 °F)
For forehead temperature: 32,0 – 42,9 °C (89.6 °F – 109.2 °F)
For forehead temperature: 32,0 – 42,9 °C (89.6 °F – 109.2 °F)
For forehead temperature: 32,0 – 42,9 °C (89.6 °F – 109.2 °F)
For object surface temperature: 0 – 100 °C (32 °F – 212 °F)
For object surface temperature: 0 – 100 °C (32 °F – 212 °F)
For object surface temperature: 0 – 100 °C (32 °F – 212 °F)
For forehead temperature: 35,0 °C – 42.0 °C: ± 0,2 °C (95.0 °F – 107.6 °F: ± 0.4 °F)
For forehead temperature: 35,0 °C – 42.0 °C: ± 0,2 °C (95.0 °F – 107.6 °F: ± 0.4 °F)
For forehead temperature: 35,0 °C – 42.0 °C: ± 0,2 °C (95.0 °F – 107.6 °F: ± 0.4 °F)
For forehead temperature: 35,0 °C – 42.0 °C: ± 0,2 °C (95.0 °F – 107.6 °F: ± 0.4 °F)
Outside this range: ± 0,3 °C (±0.5 °F)
Outside this range: ± 0,3 °C (±0.5 °F)
Outside this range: ± 0,3 °C (±0.5 °F)
Within ±0,3 °C (±0.5 °F)
Within ±0,3 °C (±0.5 °F)
0,1 °C / 0.1 °F
0,1 °C / 0.1 °F
Temperature: 10,0 °C – 40,0 °(50.0 °F – 104.0 °F)
Temperature: 10,0 °C – 40,0 °(50.0 °F – 104.0 °F)
Temperature: 10,0 °C – 40,0 °(50.0 °F – 104.0 °F)
Temperature: 10,0 °C – 40,0 °(50.0 °F – 104.0 °F)
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Atmospheric pressure: 70 kPa – 106 kPa
Atmospheric pressure: 70 kPa – 106 kPa
Atmospheric pressure: 70 kPa – 106 kPa
Temperature: -25,0 °C – 55,0 °C (-13.0 °F – 131.0 °F)
Temperature: -25,0 °C – 55,0 °C (-13.0 °F – 131.0 °F)
Temperature: -25,0 °C – 55,0 °C (-13.0 °F – 131.0 °F)
Temperature: -25,0 °C – 55,0 °C (-13.0 °F – 131.0 °F)
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Relative humidity: 15 – 95 %
Atmospheric pressure: 70 kPa – 106 kPa
Atmospheric pressure: 70 kPa – 106 kPa
Atmospheric pressure: 70 kPa – 106 kPa
149 x 85 x 44 mm
149 x 85 x 44 mm
110 g
110 g
≥38 °C (≥100.4 °F)
≥38 °C (≥100.4 °F)
IP22
IP22
Internally powered ME equipment
Internally powered ME equipment
Type BF applied part, including the whole unit
Type BF applied part, including the whole unit
Continuous operation
Continuous operation
V1.0
V1.0
Countermeasures or solutions
Countermeasures or solutions
Replace with new batteries.
Replace with new batteries.
8
8
18/10/2020 22:32
18/10/2020 22:32

Werbung