3.3
OPERATING DATA CONEL STREAM
Property
Noise level
Insulating material class motor
Temperature conveying medium
Drinking water connection
Max. plant pressure
Max flow rate in RW operation
Max flow rate in TW operation
Quality conveying medium
Manual switching mode
Pump switching machine
Class
Energy consumption Standby
Valve
Shock absorbers
Pressure gauge
3.4
Q/H DIAGRAM CONEL STREAM
Chart 3.4.1.1 Q/H Chart Conel Stream
Conel Stream
58db
Class F
+15°C - +40°C
DN 17 / max. 4 bar
6 bar
4.8m3/h
4.0m3/h at 4 bar
Clean, free of solids or grinding particles, non-viscous, non-ag-
gressive, non-crystallized and chemically neutral, similar to the
properties of water
Yes
With pressure-dependent switch-on and flow-dependent
shutdown
IP 42
approx. 1.4 W
Yes, integrated in the pump switching machine
Yes, integrated in the pump switching machine
Yes, integrated in the pump switching machine
57