Media Quality Of The Water - Conel STREAM Bedienungsanleitung

Trinkwassertrennstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Dealing:
Temperature ranges
of the media to be
promoted:
Operation:
Attention:
Under no circumstances must the Conel Stream be „dry" (i.e. in the dry state) - Dama-
ges are most likely the result.

1.4.2.7 Media quality of the water

hydrological data
PH value
conductivity
total hardness
carbonate hardness
Chloride CL
Sulfate So4
Ammonium
Iron Fe
Manganese
solid amount (sand)
solid size
• The Conel Stream must not be exposed to avoidable shocks or collisions;
• Temperature conveying medium: > (frost-free) up to + 40°C.
• The Conel Stream is suitable for continuous operation.
• Prolonged operation of the Conel Stream with a throughput below the
minimum value indicated on the data sheet can cause excessive heating
that is harmful to the pump.
• At water temperatures close to 400C, the minimum throughput must be
increased depending on the temperature. For liquids other than water,
please contact Customer Service.
maximum
6.0 -8.0
< 150
< 15
< 4
< 100
< 150
< 1
< 0.2
< 0.1
< 150
< 2.0
49
Units
mS/m
°dH
°dH
mg/l
mg/l
mg/l
mg/l
mg/l
g/m3
Mm