62
8
INSTALLATION AND INSTALLATION
OF THE CONEL STREAM
8.1

SECURITY

DANGER: Danger to life due to deadly electric shock!
• All assembly and commissioning activities may only be carried out by professional
and knowledgeable personnel who have been suffi ciently informed by studying the
operating instructions in-depth;
• The electrical installation may only be carried out by certifi ed personnel, in this
case the applicable standards and regulations of the respective country in which
the Conel Stream is to be used must be observed;
• This personnel must have read and understood this operating manual;
• Before the activities begin, the system shall be switched off without voltage and
secured against unauthorized or unintentional re-entry;
• Ensure that the Conel Stream cannot be put into operation without authorization
or unintentionally during assembly, installation or initial commissioning;
• Refer to unauthorized persons (especially children, adolescents) or animals from
the fi eld of work/activity.
DANGER: Danger of stumbling and falling!
• Ensure a tidy work area – avoid stumbling and risk of falling.
• If you need to enter the store – pay attention to your personal fuse by holding/
carrying straps;
• It is possible that life-threatening gases can leak in the storage tank - there is an
acute danger to life.
• Avoid open fi re, do not smoke
8.2

WALL

Install the Conel Stream:
• in a dry and frost-free room, e.g., cellar;
• in a room with fl oor drain to the public canal or lifting system;
• at least 30 cm (possibly larger) below the ceiling of the room, measured from the top edge of the
device (necessary for possible maintenance /service work);
• on a fl at wall (prevents tensions on the Conel Stream);
• horizontal (mandatory for orderly operation);
• above the maximum water level of the Speicher (see Figure 7.2.1);
• above the backlog level of the public sewer network (see Chapter 8.6 for details on this).
• Keep the wall bracket (included in delivery) horizontally to the place of attachment and draw moun-
ting holes;
• Drilling mounting holes (8mm drills) and putting dowels.
• Attach the wall bracket to the wall with screws and washers;
• Make sure that the wall bracket is horizontally aligned.