6.1.3
INSTRUCTIONS FOR K12-TD
1. Position the unit in a vertical position with the fan guard
cowling on a flat, stable surface.
2. Remove the (915) screws.
3. Remove the (902.2) nuts.
4. Remove (902) screws from the (162) cover.
5. Remove the (162) cover by using the two threaded holes
placed on cover itself.
6. Remove the (900) screw and (365) washer.
7. Remove the (321) bearing and (360) bearing cover working
through the extractor.
8. Remove the (951) spacer ring.
9. Remove the (231) impeller through the extractor if
necessary and (940) key.
10. Remove components (103) and (104) and place them
together, by using the two threaded holes placed on (104)
intermediate cover.
11. Remove the (934) spacer.
12. Remove the (935) shims-be careful not to misplace.
13. Remove the (230) impeller through the extractor if
necessary and (940) key.
Clean and reassemble following the instructions in reverse
order, and forming the (423) seal using Loctite 5970 or a similar
product after having carefully cleaned the surfaces previously
sealed.
It's important not to reverse the position of the (230) and
(231) impellers
951
940
900
365
Extraction's
threaded holes
423
940
Extraction's
threaded holes
321
915
360
934
935
162
902
231
103
104
902.2
230
Flat, stable support
surface
6.2

REPLACEMENT SOUND-ABSORBING PANELS

If needed, replace the foam sound-absorbing panels,
proceed as follows
1.
Position the unit in a horizontal position with its brackets
on a flat, stable surface.
2.
Remove the (906) screws.
3.
Remove the (700) silencers from the unit, being careful not
to lose the (424) gaskets.
4.
Remove the (720) soundproofing from the silencer
housings.
5.
Retrieve the (710) support mesh.
6.
Replace and reassemble-proceeding in reverse order,
remembering to include the (424) gaskets.
6.3

LIFESPAN OF BEARINGS

Under
normal
CHARACTERISTIC DATA – page 3/4) the machine's bearings
have to be replaced after a maximum of 25,000 working hours
or not more than 4 years.
Any use other than the intended use of the
unit may cause serious injury and even
death!
The bearings may only be replaced:
If the instructions, parts list, and section/exploded view of
the relevant unit are available.
After having carefully read, fully understood, and complied
with this
operating manual ("SAFETY STANDARDS"
"STORAGE AND TRANSPORT" and "INSTALLATION").
In
conformity
"INTENDED USE".
By qualified personnel, that is, personnel whose training,
instruction, experience, knowledge of standards, regulations,
accident prevention procedures, and operating and service
conditions, makes them capable of carrying out all the works
necessary, while being aware of and avoiding any possible
danger and/or damage.
7

COMMERCIAL CONDITIONS

All undertakings, agreements, or legal relations are
governed by the relevant sales contract. These are in no
way limited by the contents of this manual.
The
quality
of
guaranteed, as indicated in the general sales conditions.
Guarantees are regulated by the general conditions of sale.
GB - 29/74
GB - 28/69
424
906
Flat, stable support surface
operating
conditions
(values
with
the
purposes
laid
the
materials
and
workmanship
720
710
700
shown
in
down
under
is

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis