Air filter, fig. 5
Warning: The air filter must be installed before the initial
use. Using the device without air filter will damage the
compressor and void the warranty.
The air filter (15) is attached on the right side of the cylin-
der and screwed tightly.
Start-up
Warning:
Prior to initial use, the oil level must be checked!
1 Ensure the mounting location of the compressor is
clean, dry and well ventilated.
2 Make sure the oil level is correct and the air filter has
been mounted.
3 Start the compressor as described in section "Switching
the compressor on and off". If compressor is switched
on for the first time, let the compressor run without
load and with open drain valve for ten minutes so that
all components are well lubricated.
Warning: Since compressed air is escaping from the out-
let, the outlet must not be directed towards the machine
operator or persons in the surrounding area. The air emit-
ted by the device must not be inhaled. Check the pressure
control valve every day.
Switching the compressor on and off, fig. 6
1 Check the type plate on the compressor: 230 - 240 V
(or 110 – 120 V).
2 Plug the compressor cable into a standard mains socket
(240 V or 120 V) and switch the device on.
3 To turn the compressor on, lift the ON/OFF switch (3)
at the pressure switch cover (2).
4 Push the ON/OFF switch down to turn the compressor
off.

Operation

Fig. 7
1 The pressure in the tank is controlled by the pressure
switch under the pressure switch cover (2). If the set
maximum pressure is reached, the pressure switch is
activated and the motor is switched off. The pressure
will decrease in accordance with the air used by the
tool that is connected to the compressor until the set
minimum pressure is reached. The pressure switch then
turns the motor on again. The operator of the device
should keep in mind that the motor switches on and
off during operation due to the increasing and decrea-
sing pressure in the tank. The motor starts without any
previous warning.
2 The maximum and minimum pressure values were set
in the factory. These settings must not be modified.
3 All accessory parts have been connected to the adjus-
international 73