Herunterladen Inhalt Inhalt Diese Seite drucken

Commissioning; Interface Description - Bosch Rexroth SMdev Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
12/40
Bosch Rexroth AG

5 Commissioning

5
Commissioning
Commissioning requires the BS300 and
firmware V1.410 or higher.
You can find further information on
installation and operation in the chapter
"DeviceNet communication" (3 609 929
A27) of the system documentation on the
BS300 CD.
5.1

Interface description

Figure 1: Open connector, grid dimensions 5.08 mm,
5-pin, pins
Pin Signal Description/Function Color
1
V–
0 V reference potential black
2
CAN_L Bidirectional data
signal
3
Drain/
Shield and/or
Shield
protective ground
4
CAN_H Bidirectional data
signal
5
V+
24 V power supply
Table 2:
Connector assignment
V+
5
CAN_H
4
SHIELD
3
CAN_L
2
1
V-
blue
blank
white
red
SMdev | 3 609 929 A77/06.02
Suitable connection plugs:
Type
Plug component with screw
flange, dual row
Type: TMSTBP 2.5/ 5-STF-5.08
ABGY AU,
item no. 1853201
Plug component with T-shape
and screw flange, single row
Type: MSTB 2.5/ 5-STF-5.08
ABGY AU,
item no. 1882832
Table 3:
Plug types
An ID card should be placed on the plug to
identify the connections by color:
Type
ID card,
4-color, self-adhesive
Type SK 5.08/3.8 DN,
item no. 1965458
Table 4:
ID card type
Do not install lines while the
network is active.
Supplier
PhoenixContact
PhoenixContact
Supplier
PhoenixContact

Werbung