Herunterladen Inhalt Inhalt Diese Seite drucken

Io-Link Process Data; Process Data In - Balluff IO-Link BES M12MG1-YIC60B-S04G Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES M12M_1-YIC_0_-S04G
Inductive sensors
6
Basic functions (continued)
6.6

IO-Link process data

6.6.1

Process Data In

The master receives 3 bytes of process data from the
sensor (M-Sequence type: TYPE_2_V).
Byte 0
23
22
21
20
19
18
Bit
Parameter name
0
BDC1
1
Out of range
2
Switch Count: Speed
too low
3
Switch Count: Speed
too high
4
Teach active
5
Teach successful
6
Teach error
7
Switch Count: Count
limit / Speed ok
Tab. 6-8:
Output data
www.balluff.com
Byte 1
17
16
15
14
13
12
Byte 2
Description
Binary Data Channel 1: Contains
object detection information
Collision danger Sensor-Target,
target outside detection range
Switch count feature: Current swit-
ching frequency is less than the set
limit. (Lower Limit)
Switch count feature: The current
switching frequency is greater than
the set limit. (Upper Limit)
Teach procedure active
Teach procedure ended successfully
Teach procedure not successful
Switch count feature: The current
switching frequency is within the
limits. (Lower and Upper Limit)
11
10
9
8
7
6
1
Active
Target too close/far
away: Teach procedure
blocked
Active
Active
Teach procedure active
Last teach procedure
completed successfully
Last teach procedure
not completed success-
fully.
Active
Byte 2
5
4
3
2
1
0
Value
0
Inactive
Target is in detection
range.
Inactive
Inactive
Teach procedure not
active
No teach procedure yet
completed or last teach
procedure was not
successfully completed.
No teach procedure yet
completed or last teach
procedure was success-
fully completed.
Inactive
english
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis