BAE SA-OH-064-_P-DP02 / BAE SA-OH-064-_P-S75G
Photoelectric Sensors
7
Operation
7.1
Switching profile
7.1.1
Description
Sensor Principle / Evaluation Logic
The sensor performs the detection as a clocked signal that
is evaluated for switching signal generation.
The definition of the switching points is realized using a
setpoint which is determined by the position of the RES
switch and the potentiometer SENSITIVITY.
Switchpoint Logic
With switching logic Light on/High Active, the switch
output switches to high if the current signal value is greater
than the set setpoint. With Dark on/Low Active this logic is
inverted.
Light On/High Active
Low
SP1
Fig. 7-1:
Switchpoint logic Light On/High Active
Dark On/Low Active
High
SP1
Fig. 7-2:
Switchpoint logic Dark On/Low Active
12
english
High
Signal value
Low
Signal value
7.1.2
Switching point
Only one switching point (setpoint) is defined.
Switching behavior:
–
Signal value ≥ switching point plus a defined
hysteresis: Output active
–
Signal value ≤ switching point minus a defined
hysteresis: Output inactive
Low
SP1-Hys
SP1+Hys
Fig. 7-3:
Single Point Mode
7.1.3
Sensitivity setting
1. First select sensitivity with the RES switch.
Positions:
– St.: High range, large hysteresis
– Hi.: Lower range, small hysteresis, high resolution
2. Then set the switching point with the rotary
potentiometer.
High
Signal value