Electrical installation
6.2.2

Installing the battery pack

NOTICE
Incorrect calculation of the remaining charge!
► When inserting or changing the battery pack, only use new battery packs.
Exception: If the currently used battery pack is removed, e.g., during
maintenance, it may be used again.
Install battery pack:
1. Loosen the screw (Fig. C 1).
2. Remove the lid (Fig. C 2) of the battery box.
3. When changing the battery pack, disconnect the cable connector (Fig. C 5)
and remove the empty battery pack from the battery box.
WARNING
Risk of explosion!
If non-original Dräger battery packs are used, an explosion may occur.
► Use only the Dräger LBT 05** (see "Accessories and spare parts", page 63)
battery pack
4. Release the seal on the new battery pack and connect the cable plug of the
battery pack (Fig. C 5).
The cable plug of the battery pack must engage when it is inserted.
5. Insert the battery pack in the battery box.
WARNING
Risk of explosion!
A damaged cable can lead to a short circuit on the battery box.
► When closing the battery box, pay attention to the cable to avoid damage.
6. Reattach the battery box lid.
7. Loosen the screw (Fig. C 1).
6.2.3
Installing the battery box
Install the battery box:
1. Connect grounding cable to fastening screw for potential equalization (Fig.
A 17).
46
Instructions for use
|
Dräger Polytron
WARNING
Risk of explosion!
If non-original Dräger battery boxes are used, an explosion may occur.
► Only use battery box Dräger LBT 03** (see "Accessories and spare parts",
page 63).
2. Insert the battery box (Fig. A 2).
3. Close the gas detector:
a. Place the housing cover (Fig. A 1) in its final position (Dräger logo is
horizontal).
b. Turn the housing cover under slight pressure approx. 20°
counterclockwise until the housing cover rests on the sealing ring on the
housing.
c. Press the housing cover forcefully and evenly onto the sealing ring.
d. Slowly turn the housing cover approx. 20° clockwise to the stop in the
end position.
e. Screw in the locking screw (Fig. A 14) until the housing cover is
prevented from being screwed open.
NOTICE
► If a new battery pack has been inserted, reset the battery counter.
6.2.4
Resetting the battery counter
Can be performed within 10 minutes of switching on the gas detector.
Resetting the battery counter:
● Hold magnetic pin onto mark (Fig. A 12) for 5 seconds.
 Blue and yellow LEDs are activated simultaneously for 5 seconds.
✓ The battery counter is reset.
This feature is also available in PolySoft. It can be executed at any time.
®
6100 EC WL, Dräger Polytron
®
Repeater WirelessHART
®