Malfunction
Automatic gun does
not shut air off.
Corrosion on air cap
thread, material pas-
sage or nozzle head.
Air leaks from in-
spection hole of ma-
terial flow control or
regulating cap.
Material leaks from
behind the paint
needle seal through
the gun body inspec-
tion hole.
Automatic gun

13. Customer service and spare parts

Accessories, spare parts and technical support may be obtained from
your SATA dealer.
Automatic gun spare parts
See enclosed Technical Data Sheet for list of spare parts.
140
Cause
Soiled control piston
seat or worn seal
retainer.
Control air pressure
is constantly present.
Unsuitable cleaning
solution.
Defective seal retain-
er (air side).
Defective seal or
sleeve.
Defective paint nee-
dle seal.
Paint needle clogged
or damaged.
Contamination be-
tween paint needle
tip and fluid tip.
Damaged nozzle set. Replace nozzle set
Corrective action
Clean control piston
seat. Replace seal
retainer if necessary
(see chapter 10.6).
Release control air
pressure.
Replace nozzle head.
Heed cleaning in-
structions (see chap-
ter 10.3).
Replace paint needle
seal retainer (see
chapter 10.3).
Replace seal or
sleeve (see chapter
10.5).
Replace paint needle
seal retainer (see
chapter 10.3).
Replace nozzle set
(see chapter 10.1).
Clean fluid tip and
paint needle.
(see chapter 10.1).