Herunterladen Inhalt Inhalt Diese Seite drucken

Gas Adjustments; Connecting To Lpg - steel ADAGIO Gebrauchsanweisung

Kochmodule-herde
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Instructions for the installer
+
3.8

Gas adjustments

The injectors not supplied with the appliance should be requested from the Service Centre.
If the cooking appliance is set up for a different type of gas than that available, its injectors must be
replaced, the minimum flow regulated and the rubber-holder changed. In order to replace the
injectors in the cooking hob, it is necessary to carry out the following operations:
For cooktops, the Data Label is located on the underside of the appliance. A duplicate label is
supplied to adhere in an accessible area adjacent to the appliance. For cookers, the label is
situated in the appliance drawer. This appliance is suitable for Natural Gas and Propane; ensure
that the available gas supply matches the Data Label.
If the cooking appliance is set up for a different type of gas than that available, its injectors must be
replaced, the minimum flow regulated and the rubber-holder changed. In order to replace the
injectors in the cooking hob, it is necessary to carry out the following operations:
remove the pan supports;
remove the burners and burner caps (Fig. A);
take out the injector (Fig. B) and replace it with one
suitable for the new type of gas (see "G
" on page 76-77);
INJECTORS TABLE
replace the gas label (on the rear of the appliance) with
the new one provided with the injectors kit;
refit all parts by following the disassembly instructions in
reverse order and taking care to position the burner cap
correctly on the burner.
3.8.1
Minimum flow of valved cooking hob taps
Switch on the burner and turn the control
knob towards the minimum flow position ;
remove the knob;
using a screwdriver, adjust the internal screw
Z until the correct low flame is obtained;
refit the knob.
Unscrew the adjustment screw Z to increase the flow, or tighten it to reduce the flow.
The adjustment is correct when the low flame measures approximately 3 or 4 mm.
For butane/propane, the adjustment screw should be tightened all the way.
When changing quickly from maximum to minimum flow and vice versa make sure that the
flame does not go out.
3.9

Connecting to LPG

Gas may only be connected to a gas installation, whether bottle supplied or other.
Gas may only be connected to a gas installation, whether bottle supplied or other.
When converting from Natural Gas to Propane ensure that the NG regulator is removed and
replaced with the Test Point Assembly. A gas regulator suitable for a supply pressure of 2.75kPa
should be part of the gas tank supply and should be adjusted with the Wok burner operating at
maximum. Replace the old data plate with one which is suitable for the type of gas for which the
appliance has been regulated.