START

START:
The heat pump usually covers a family's need for hot water throughout the year. VT167 E is equipped with a coil
built into the hot water tank so that preparing of hot water can occur through the house central heating system or the
heat pumps surplus heat can be used to heating the bathroom or other small space on cool summer evenings, where
you do not have the boiler started up. Refer to page 19 "Connection Example". The first launch of in accordance with
the instructions installed water pump to be made by a person skilled in accordance with the following. The total
construction is filled with water and examined for leaks. In this context there must be a vent. Heat pump may first
start up when the tank is filled with water. At first launch, or when the container has been emptied of water, there
must likely be an operating time of 8 to 10 hours at an air temperature of approx. 15°C to reach a water temperature
of 45-55°C. Choose VP running on the control panel to start, perhaps in combination with supplementary heating.
NOTE: The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge unless they have been given supervision or instruction. Children being
supervised not to play with the appliance.
HEATING PRINCIPLE:
The heat pump operates on the air to water principal; i.e. the air is drawn through an evaporator and cooled.
In the compressor the thermal energy of the air is transformed to a higher temperature and through a heat exchanger
transferred to the water in the boiler.

TECHNICAL DATA

TECHNICAL DATA:
Dimensions:
Weight without packaging:
Voltage/frequency:
Heat pump input:
Heat pump output:
High supplementary heating:
Safety with high supplementary heating:
Thermostat for supplementary heating:
Refrigerant:
Quantity of air:
Air temperature: VT167OHE/VT167 E/VT3132
Boiler: VT167OHE
Boiler: VT167 E
Working pressure:
Anode:
Water temperature:
Water capacity:
Idle consumption - at 15 °C air temperature
and 55 °C water temperature - measured according DIN 8947: 0.7 kWh/24h
Water connections
Heat exchanger, heat surface VT167 E:
*According to ASHRAE
– Cold water:
– Hot water:
– Condensation water:
– Heat exchanger:
– Circulation connection:
H: 1768 mm, Ø707mm
114-137-159 kg
230 V / 50 Hz Phase-Neutral-Earth
395 Watt*
1421 Watt*
1500 Watt/230 V
Minimum 13 A
Set at 65°C, controlled via the display
See nameplate
Min/Max. 200/300 m3/h
Min. -10 °C to max. +35 °C
Enamelled, 266 l.
Enamelled, 258 l.
Max.1 MPa / 10 bar
Magnesium - 5/4" RT
Adjustable - max. 62 °C
850 L / 24h
1" RT
1" RT
1/2" RT
1" RT
3/4" RT
1.00 m² (5.90 L)
6