Display View: Service Menu; Fan Control; Alarm Handling - SWISSTHERM VT167 OHE Bedienungs Und Installationsanleitung Handbuch

Brauchwasser-wärmepumpe
Vorschau ausblenden Andere Handbücher für VT167 OHE:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ReDays
0-99
Status of remaining days of the holiday where water temperature lowers to "T2 min"
0
Boost
"Off", "On"
Activate if in need of fast hot water production. Activates "HP+EL" until "T max" is reached though stops
Off
automatically after 1 hour.

DISPLAY VIEW: Service menu

Only for the installer
Language
Danish, German, English, Spanish, French, Polish, Sloven, Italian
English
Software
SERVICE MENU – Only for the installer.
The menu "software" tells which Software-Version is entered.
1.29
The number "1.29" is the entered Version
Defrost
SERVICE MENU – Only for the installer
"Defrost" shows, after which the following 3 defrosting methods works:
Gas
"GAS", for V3130 / VT167 E / VT3132
Service Def.None, Def.Gas
T max
SERVICE MENU – Only for the installer
55°C
Temperature "T max". Here can the maximum desired operating temperature be adjusted. The
temperature adjusted under "T max" is afterwards the highest possible temperature in menu
"SETPOINT".
"T max" can of 5°C to 62°C be selected. Please note, that efficiency of the heat pump is reduced at
higher temperatures = higher current consumption.
Compressor protection: A timer of 5 minutes from compressor stop to new start is inserted.

FAN CONTROL:

The fan has 2 speed settings which can be adjusted in the menu "FanOper". Normally, the highest speed should be used.
If the heat pump in some cases would interfere, the low speed setting can be selected without having a significant
influence on the heat pump efficiency.
With air duct connections the high speed setting must be used. The fan can in the "FanCon" setting be connected so that
constant ventilation can be made. The fan will in the setup 0 be disconnected with heat pump. In setup "Low" it runs on
low speed and in setup "High" it runs high speed with heat pump disconnected.

ALARM HANDLING

ALARM HANDLING:
There are 3 alarm levels. The display can show 3 different alarms at the same time. The alarm must be reset by pressing
the control button push/rotary at the control panel.
The information alarm it does not affect the heat pump, but tell the user that there is a problem, which must be solved as
soon as possible. (Alarm no. 8, 9 and 10).
The cooling circuit alarm warm water production with the compressor stops. When the supplementary heating is chosen,
it takes over the hot water production to the Setpoint. (Alarm no. 3, 4, 5 and 6).
Alarm for the whole heat pump warm water production stops completely. It acts probably over a defective operating
sensor. (Alarm no. 1 and 2).
The user can see the alarms in the alarm menu, where also the alarms are acknowledged. The error must be eliminated and
the alarm has to be acknowledged, before the normal operation will take place again. If the error is not eliminated the
alarm will still be on. In the case several simultaneous alarms, they are placed in row. The alarms become shown in a
priority list.
Pressure switch alarm 5 & 6 will be handled in the following way
.
14