First error, alarm no. 5 shows in the display. The heat pump stops. Automatic restart after resetting the alarm. With
alarm no. 5 the red lamp no. 3 flashes. If the error is eliminated it automatically switched to orange flash, and after
receipt on activity or standby (= constantly orange or green light).
Second error less than 6 hours after first error, alarm no. 6 shows in the display. The heat pump stops and the alarm
shows. The heat pump can only be started by resetting the alarm. At the alarm no. 6 the red lamp no. 3 will flash,
after pressure switch and receipt on activity or standby(= constantly orange or green light). Resetting the alarm by
pressing the rotary button.

ALARM STATUS IS POINTED TO INDICATORS:

Signal lamp (3) for heat pump flashes red: Information- or coolant system alarm. Both signal lamps (3 + 4) flash:
Operating sensor defectively, no heating possible.

ALARM OVERVIEW:

Number
Alarm lamp:
No. 3
1
X
(red)
2
X
(red)
3
X
(red)
4
X
(red)
5
X
(red)
6
X
(red)
8
X
(red)
9
X
(red)
10
X
(red)

ANODE

ANODE:
Hot water tank is internal corrosion protected with enamel. There are in the enamel few small pores, etc., that are not
covered by the enamel. To completely prevent corrosion there is mounted an anode in the middle of the tank to
protect these pores (some models has 2 pcs.). One should ensure that the anode is always intact. This should be done
by inspecting once every year and if necessary replace it. For models with signal anode will emerge an alarm when it
needs replacing. This alarm does not lock the daily operation.

SIGNAL ANODE:

Models, that are equipped with signal anode. The anode menu will show "AUTO", and alarm nr. 9 will show, if the
anode is used and has to be replaced. If the anode menu shows "manual", there are none automatic control function
for used anode. See page 18 "maintenance of the anode". Also note that models with signal anode is not able to have
features like solar cells, holiday and boost functions which will not be shown in the display menu.
Name
No. 4
X
Short circuit in the temperature sensor
(red)
in the top of the tank.
X
Temperature sensor in the top of the
(red)
tank is switched off.
Short circuit in the temperature sensor
for the evaporator.
Temperature sensor for the evaporator
is switched off.
First pressure switch alarm
Second pressure switch alarm
Temperature sensor „Temp 1" short
circuit.
Corrosion anode diminished
Legionella temperature does not reach
Remark
Heat pump and alternative heating stop
Heat pump and alternative heating stop
Compressor stops
Compressor stops
Compressor stops and starts again automatically,
if the error is eliminated, possibly resetting
Compressor stops and starts only again after
resetting and user receipt
Information
Information
Information
15