3. Re-open the steam handle.
4. Heat and/or froth the liquid.
5. After frothing or heating, release the steam into the drip tray to keep the holes of the steam nozzle
clean.
Risk of injury
Always keep the steam nozzle underneath the surface of the liquid while heating or
frothing in order to avoid spraying.
Important
Clean the steam nozzle and the steam dispenser after every application with a non-
abrasive, damp cloth; this removes possible liquid residues.
Risk of injury
Avoid skin contact with the steam dispenser while cleaning!

7. CLEANING AND MAINTENANCE

Regular and accurate care is very important for the performance, the longevity and the safety of your
machine.
Caution!
Always switch the machine (power switch in lower position) off, disconnect the power cord
and let the machine cool down to room temperature (for at least 30 minutes) before
cleaning.
Never immerse the machine in water. Improper cleaning may result in the risk of electric
shock.

7.1 General cleaning

Daily cleaning:
Portafilters, filters, water tank, drip tray, drip plate of the drip tray and tamper require daily cleaning with
warm water and/or with a food safe detergent.
Portafilter, drip tray, drip plate and water tank are not suitable for the dish washer.
Clean the shower screen and the group gasket in the lower part of the group and remove visible dirt
without dissasembling the parts.
Cleaning as necessary:
Clean the steam and hot water valve after every use.
Clean the body when the machine is switched off and cold.
Depending on usage, please refresh the boiler water every 2
extracting about 0.8 L of hot water from the steam/hot water wand.
Use a soft and damp cloth for cleaning.
Never use abrasive or chloric detergents!
Empty the water drip tray regularly and do not wait until it is full.
Translation of the German original user manual