Chapter 3. Routine Maintenance
Table 8: Mechanisms and Settings
Make sure mechanisms are serviceable and settings are correct to prevent unsatisfactory
Mark
Do this each
1 2 3 4 5 6
x 2400 hours
x
200 hours
x
200 hours
x
200 hours
x
600 hours
x
600 hours
PELLERIN MILNOR CORPORATION
performance.
Component
controller circuitry
water pressure regulator for
optional supply injector
compressed air mechanisms
bath level sensor that uses air
pressure
push-down system that uses
compressed air
door seal system that uses
compressed air
26
More Data
Examine wiring and connections in electrical
boxes. Look for corrosion, loose connections.
See
Section 3.1.3
See
Figure
10. Value: 28 PSI (193 kPa).
See
Supplement
2,
Figure 14
Examine the air tube and connections. See
Figure 11
Look at the shell when the machine operates
to make sure there is no irregular movement
of the shell. See
Supplement 4
Look at the doors when the machine operates
to make sure there is no evidence of a door
leak. See
Supplement 3