Wall-mounting the appliance and levelling it
First remove the protective film from the back of the
1.
appliance and, following installation, remove the rest of the
film.
When mounting the appliance, ensure that it engages
2.
properly with the mounting supports.
If required, the appliance can be moved to the right or to the
3.
left.
Firmly tighten the screws for the mounting supports. Hold the
4.
bracket firmly when doing so. ¨
If no duct is to be fitted, screw in the two locking screws
5.
without the bracket. ©

Connecting the pipes

If the extractor hood is to be operated in exhaust-air mode, the
pipes must be connected. If the extractor hood is to be
operated in air-recirculation mode, an optional accessory must
be fitted. To do this, refer to the installation instructions
provided.
Note: If an aluminium pipe is being used, smooth the
connection area beforehand.
Exhaust air pipe, dia. 150 mm (recommended size)
Fit the exhaust air pipe directly to the air-pipe connector and
seal the joint.
Exhaust air pipe, dia. 120 mm
Fit the reducing connector directly to the air-pipe connector.
1.
Attach the exhaust air pipe to the reducing connector.
2.
Use suitable means to seal both joints.
3.

Attaching the flue duct

If the extractor hood is to be operated in exhaust-air mode, a
flue duct must be fitted.
The flue duct does not need to be fitted for air-recirculation
mode.
:
Risk of injury!
From sharp edges during installation. Always wear protective
gloves while installing the appliance.
:
Risk of electric shock!
Components inside the appliance may have sharp edges.
These may damage the connecting cable. Do not kink or pinch
the connecting cable during installation.
Separate the flue duct sections by removing the adhesive
1.
tape.
Remove the pieces of protective film from both flue duct
2.
sections.
Push one flue duct section into the other.
3.
Notes
To prevent scratches, lay paper over the edges of the outer
flue duct section to protect the surface.
The slots of the inner flue duct section point downwards.
Place flue ducts sections on the appliance.
4.
Slide the inner flue duct section upwards, attach it to the left
5.
and right sides of the retaining bracket, and then slide it
down to engage it. ¨
Screw the flue duct section to the sides of the retaining
6.
bracket using two screws. ©
Clip the lower flue duct section in at the retaining bracket.
7.
The connection cable must not be damaged. ª
Note: If an air-recirculation optional accessory has been fitted
and the extractor hood is to be operated without a flue duct, the
cable must be wound onto the connector.
29