REQUEST FOR THE INDICATION OF INSTALLATION INFORMATION
1. RECORD OF INDOOR UNIT MODEL AND INSTALLATION SITE
No.
1
2
3
4
MODELNAME
INSTALLATION
SITE
No.
11
12
13
14
MODELNAME
INSTALLATION
SITE
No.
21
22
23
24
MODELNAME
INSTALLATION
SITE
No.
31
32
33
34
MODELNAME
INSTALLATION
SITE
No.
41
42
43
44
MODELNAME
INSTALLATION
No.
SITE
51
52
53
54
MODELNAME
INSTALLATION
No.
SITE
61
62
63
64
MODELNAME
INSTALLATION
SITE
2. RECORD FOR SETTINGS (CONTENTS SEE INSTALLATION MANUAL)
SETTING
VALUE
REMARK
DATE
3. RECORD OF INSTALLATION DATE
DAY
MONTH
YEAR
6. AFTER EQUIPPING, PLEASE PUT IT ON THE BACK SIDE OF THE FRONT PLATE.
f
g
a
Allgemeine Sicherheitshinweise
b
Installations- und Betriebsanleitung
c
Aufkleber für zusätzliche Kältemittel-Füllung
d
Aufkleber für Installationsinformationen
e
Etikett für fluorierte Treibhausgase
f
Mehrsprachiges Etikett für fluorierte Treibhausgase
g
Beutel für Zusatzrohre
11.3

Zusatzrohre: Durchmesser

Zusatzrohre (mm)
Gasleitung
▪ Anschluss vorne
ID Øa
ID Øb
▪ Anschluss unten
ID Øa
OD Øb
Flüssigkeitsleitung
▪ Anschluss vorne
ID Øb
ID Øa
▪ Anschluss unten
ID Øb
ID Øa
11.4
Die Transportstütze entfernen
HINWEIS
Wird die Einheit mit befestigter Transportstütze betrieben,
können extreme Vibration und Lärm erzeugt werden.
Die Transportstütze für den Verdichter muss entfernt bleiben. Es ist
unter dem Bein des Verdichters eingesetzt und dient dazu, die
Einheit beim Transport zu schützen. Orientieren Sie sich an der
Abbildung und der nachfolgenden Beschreibung.
1 Die 2 Transportstützen-Befestigungsbolzen entfernen.
2 Die Transportstütze entfernen - siehe Abbildung unten.
RXMLQ8 + RXYLQ10~14T7Y1B*
VRV IV System Klimagerät
4P543426-1B – 2020.10
c
d
e
REQUEST FOR THE INDICATION OF ADDITIONAL REFRIGERANT CHARGING AND LEAK DETECTION OPERATION RESULT
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
5
6
7
8
9
10
1. CALCULATION OF ADDITIONAL REFRIGERANT CHARGING AMOUNT
CALCULATE THE ADDITIONAL REFRIGERANT CHARGING AMOUNT BASED ON THE FORMULA BELOW BEFORE CHARGING.
SHIPMENT (INDICATED ON THE MACHINE NAMEPLATE) AND THE ADDITIONAL AMOUNT SHOWN AS FOLLOWS :
WHEN RE-CHARGING TOTAL AMOUNT OF REFRIGERANT , CHARGE THE TOTAL OF THE AMOUNT CHARGED AT
Total indoor unit
15
16
17
18
19
20
kg
capacity connection
Total indoor unit capacity
ratio (CR)
50%< CR < 105%
8HP
0
10-12HP 14-16HP 18-20HP
0
0
0.5
OUTDOOR
ADDITIONAL CHARGING
AMOUNT
PIPE SIZE O22.2 x 0.37
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
PIPE SIZE O19.1 x 0.26
PIPE SIZE O15.9 x 0.18
TOTAL LENGTH OF LIQUID
when piping length <30m
50%< CR < 70%
105%< CR < 130%
0.5
0
0.5
0
0.5
0
1.0
0.5
25
26
27
28
29
30
UNIT
kg
(m) x 0.37
(m) x 0.26
(m) x 0.18
when piping length >30m
Total indoor unit capacity
70%< CR < 85%
85%< CR < 105%
0.7
0.3
0.5
1
0.5
1
1.5
1.0
105%< CR < 130%
1.2
1.5
1.5
2.0
PIPE SIZE O12.7 x 0.12
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
PIPE SIZE O9.5 x 0.059
PIPE SIZE O6.4 x 0.022
TOTAL LENGTH OF LIQUID
35
36
37
38
39
40
(m) x 0.12
(m) x 0.059
(m) x 0.022
kg
RYYQ8~12
ONLY FOR RYYQ8~20 MODELS
RYYQ14-16
RYYQ18-20
0.9
1.1
1.3
2. RECORD OF ADDITIONAL REFRIGERANT CHARGE AMOUNT AND RESULT OF LEAK CHECK OPERATION
45
46
47
48
49
50
DATE
AMOUNT
55
56
57
58
59
60
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
DATE
AMOUNT
SETTING
VALUE
REMARK
DATE
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
3. FOR DETAILS CONCERNING PIPING SELECTION AND CALCULATION OR HOW TO OPERATE THE LEAK DETECTION FUNCTION, PLEASE REFER TO THE INSTALLATION MANUAL.
4. MODEL NAME
5. MANUFACTURING NUMBER
4. AFTER FILLING IN THIS TABLE, PLEASE PUT IT ON THE SWITCH BOX COVER.
3P328191-1
3P328192-1
HP
Øa
Øb
8
19,1
10
25,4
22,2
12
25,4
28,6
14
8
9,5
10
12
12,7
14
12 Über die Geräte und Optionen
1
12
Über die Geräte und Optionen
12.1
Über die Außeneinheit
Die
Installationsanleitung
gilt
Wärmepumpensystem VRV IV.
Modellreihe:
Modell
RXYLQ10~14
Einzel-Modell für nicht-kontinuierliches
Heizen.
RXYLQ16~42
Multi-Modell für nicht-kontinuierliches
Heizen (bestehend aus 2 oder 3 Modulen).
Je nach Typ der gewählten Außeneinheit gibt es einige Funktionen,
die zur Verfügung stehen oder nicht. Welche das sind, ist in dieser
Installationsanleitung
an
den
angegeben. Bestimmte Funktionen haben exklusive Modellrechte.
Diese Einheiten sind für die Außeninstallation gedacht und für
Wärmepumpeneinsätze, zu denen Luft-zu-Luft- und Luft-zu-Wasser-
Anwendungen gehören.
Diese Einheiten haben (bei Einzel-Einsatz) Heizleistungen von 31,5
bis 45 kW und Kühlleistungen von 28 bis 40 kW. Diese Kombination
mehrerer Einheiten hat eine Heizleistung von 50 bis 135  kW und
eine Kühlleistung von 45 bis 120 kW.
Die Außeneinheit ist konzipiert für den Betrieb im Heizmodus bei
Umgebungstemperaturen von –25°C  WB bis 15,5°C  WB, im
Kühlmodus bei Umgebungstemperaturen von –5°C DB bis 43°C DB.
12.2

Systemanordnung

a
i
b
c
d
c
g
g
a
VRV IV Wärmepumpen-Außeneinheit
b
Kältemittelrohre
c
VRV Inneneinheit mit direkter Dampfdehnung (DX)
d
VRV LT Hydrobox (HXY080/125)
e
BP-Box (erforderlich zum Anschluss von Inneneinheiten
mit direkter Dampfdehnung (RA) von Residential Air (SA)
oder Sky Air (DX))
f
Inneneinheiten mit direkter Dampfdehnung (RA) von
Residential Air (DX)
g
Benutzerschnittstelle (je nach Typ der Inneneinheit fest
zugeordnet)
h
Benutzerschnittstelle (drahtlos, je nach Typ der
Inneneinheit dediziert)
1
für
das
inverterbetriebene
Beschreibung
jeweils
betreffenden
Stellen
e
c
c
f
g
g
g
h
Installations- und Betriebsanleitung
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis