Chapter X Common faults and solutions

Fault
1. Computer host and display
indicators do not come on.
2. Display screen does not come on.
3. Printing fails or print quality is
poor.
4. Computer host cannot find any
camera.
5. Flash plate light does not come
on.
6. Camera cannot capture any
target board.
7. Camera works normally and can
capture target board, but vehicle
pushing arrow does not appear.
8. Both left and right vehicle pushing
arrows keep flashing in the process
of vehicle pushing.
AE5601
Possible causes
a.Power is not connected.
b.Power switch is not turned on.
c.Power cable is damaged.
a.Display is not turned on.
b.Connecting cable between display
and computer host is faulty.
c.Display is damaged.
a.Printer is not turned on.
b.Printer paper has run out.
c.Printer is improperly set up.
d.Ink cartridge is empty.
e.Camera is improperly set up.
f.Connecting cable between camera
and computer host is faulty.
g.Camera is faulty.
a.12V switching power supply is not
turned on.
b.Connecting cable between flash
plate and switching power supply
is faulty.
c.12V switching power supply is
damaged. 。
d.Transmitting tube of flash plate is
burnt out.
a.The surface of target board is
dirty.
b.between camera and target
board.
c.Camera fails to work.
d.Flash plate fails to work.
"Remeasure" button is not clicked
during measurement.
Calibration file at C:/Whed is
missing.
中文
EN DE
RU
KO
Troubleshooting
Check power socket, fuse and cable
connection.
a.Turn on display switch.
b.Check the connecting cable
between computer host and
display, and replace the cable if it
is damaged.
c.Contact After-sales Service
Department.
a.Turn on printer.
b.Load printer paper.
c.Reinstall printer driver.
d.Replace ink cartridge.
a.Reinstall camera driver.
b.Check the connecting cable
between camera and computer
host, and replace the cable with a
new one if it is damaged.
c.Contact After-sales Service
Department for replacement of
camera
a.Turn on 12V switching power
supply.
b.Check the cable, and replace it if it
is damaged.
c.Replace 12V switching power
supply.
d.Replace with new flash plate.
a.Remove dirt with special cleaning
tool.
b.Remove the obstacle between
camera and target board.
c.Do troubleshooting according to
Fault 4 indicated in this table.
d.Do troubleshooting according to
Fault 5 indicated in this table.
Go back to the previous step, click
"Remeasure" button, and then click
"Next" button.
Contact After-sales Service
Department to obtain this file.
PT