Herunterladen Inhalt Inhalt Diese Seite drucken

Leds - Bosch Rexroth PRC7000 MGDM Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Rexroth PRC7000 MGDM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

108/118 Bosch Rexroth AG | Electric Drives and Controls

16 LEDs

Features:
At the front part of the MGDM are arranged 7 Diagnosis LEDs.
LED „ US1" supply voltage 1
Tab. 8:
State
Meaning
dark
No supply voltage
green
Supply voltage US1 available
LED „ US2" supply voltage 2
Tab. 9:
State
Meaning
dark
No supply voltage
green
Supply voltage US2 available
Tab. 10: LED „ PWR" Status internal power supply
State
Meaning
dark
No internal power supply
yellow
Internal power supply available, configuration start
green
Internal power supply available
Tab. 11: LED „ MS" Modul Status
State
Meaning
dark
Module not in operation
red
Hardware fault, switch module off and on again
yellow
Not used
flashing yellow
Not used
green
Module state ok
flashing green
Not used
Tab. 12: LED „ S" Sercos Status
State
Meaning
dark
no Sercos communication
orange
Sercos communication phase 0 is active
flashing green once,
Sercos communication phase 1 is active
then orange
flashing green 2
Sercos communication phase 2 is active
times, then orange
flashing green 3
Sercos communication phase 3 is active
times, then orange
green permanent
Sercos communication phase 4 is active
flashing yellow then
Device is in hot plug phase 0
green intermittently
flashing once
Device is in hot plug phase 1
orange then green
R911381901 | Rexroth PRC7000 MGDM