10.2 Maintenance
The lifting module only requires low maintenance. The service life of the
lifting module can be extended by suitable care measures. However, regular
checks of components, particularly of cables as well as plugged and screwed
connections are required.
Prevent fl uids from entering the lifting module and dry it with a soft piece
of cloth.
Lubricate the guide grooves with the Fin Lube EP Plus spray of Interfl on
3 842 546 150 to reduce wear and prevent running noise. Intervals: 6 months
Do not open the lifting modules.
A
Fig. 7: Lubrication points
10.3 Repair
In case of damage, completely replace the lifting module.
In systems with multiple lifting modules, remove the attachment,
e.g. the table top.
Replace the defective lifting module and perform referencing. See also section
"Referencing".
Reassemble the system.
A
3 842 559 937/2019-07, MPS: Lifting module, Bosch Rexroth AG
Maintenance and repair
A-A
21/28
559 937-07