Technical data
14.2 Ambient conditions
• The lifting module is designed for stationary indoor use in light industrial areas.
• Operating temperature: +10 °C to +40 °C
• Storage temperature –20 °C to +60 °C
• Relative humidity: max. 95%, non-condensing
• Installation height < 3,000 m
• Air pressure: 700 – 1,070 hPa
• Avoid mold, fungi. Avoid rodents and other vermin.
• Do not install or operate in the immediate vicinity of industrial equipment
producing chemical emissions.
• Do not install or operate near sources of sand or dust.
• Do not install or operate in areas that are regularly subjected to high-energy
forces caused, for example, by presses or heavy machinery.
14.3 Lifting tables according to DIN EN 1570
• For design, max. 2/3 of the admissible pressure load of the lifting
module apply.
• The lifting modules feature software and end position switches. The end
position switches are not direct opening according to DIN EN-60947-5-3
Bosch Rexroth AG, MPS: Lifting module, 3 842 559 937/2019-07