24/28
Troubleshooting
13 Troubleshooting
Warning and error messages shown on the hand switch display are
generated by the control and provide information about possible faults
and their cause.
Troubleshooting procedure
1.
Check all plug connections for correct fi tting.
2.
Check all cables for pinching or shearing points.
3.
Replace the lifting module or control unit (referencing required).
14 Technical data
Table 6: Technical data
Description
Maximum load (pressure)
Maximum load (tensile)
adm. tilting torque
Lifting velocity
Lift
Duty cycle (ON time)
Ambient temperature
Supply voltage
1
)
Protection type
Service life
Noise emission
Fig. 9:
Bending torque of the lifting module
) Connection from top and fl at covering, e.g. table top (otherwise IP40).
1
Bosch Rexroth AG, MPS: Lifting module, 3 842 559 937/2019-07
Unit
F1000
F
1000 N
500 N
M
250 Nm;
x
M
125 Nm
y
v
25 mm/s
H
350 / 410 / 500 mm
ED
T
IP53
Mx
F1600
1600 N
1200 N
18 mm/s
350 / 440 / 500 mm
10% (= max. 2 min ON, 18 min OFF)
+10 °C to + 40 °C during operation
24DC – 32DC
IP54
10,000 double lifts
< 60 dB (A)
My
F3200
3200 N
1600 N
500 Nm;
250 Nm
9 mm/s
IP54
559 937-09