7.1.11 Analog Pressure output (X2,22)
The Analog Pressure output (X2,2) is configurable:
Voltage 0-10V
Current 0-10mA
Current 4-20mA (default)
7.1.12 Cyclic memory tests
The timer perform in the background a test of the parameter memory.
If an error will be detected, then will be output a warning message "Ram
checksum error" with additional code, which is made up as follows:
Additonal code = offset + subindex
Offset:
Example: A fault in the parameters of program 11 would be displayed with the
additional code 4011, a fault in the electrode parameters for electrode 5 with the
additional code 3005.
The start of programs, which are affected from a memory error, lead to an error
message „No weld program".
Bosch Rexroth AG
1000: Global data
2000: Power unit parameter
3000: Electrode parameter
4000: Program parameter
5000: Stepper curves
6000: Tip dress curves
7000: Transformer parameter
8000: Diode parameter