REMINDERS FOR THE MAINTENANCE
TECHNICIAN
The manufacturer will not be liable for any damage or
injury resulting from failure to observe the following
rules.
•
Read this manual carefully. It provides important
information for safe installation, use and
maintenance of the appliance.
•
Disconnect the appliance electrical power supply, if
present, before proceeding with any operation.
•
Installation, conversion to a different type of gas
and appliance maintenance must be carried out by
qualified technicians authorized by the manufacturer,
in compliance with current safety standards and the
instructions given in this manual.
•
Identify the specific appliance model. The model
number is detailed on the packaging and on the
appliance data plate.
•
The appliance must be installed in a well-ventilated
room.
•
Do not obstruct any air vents or drains present on
the appliance.
•
Do not tamper with appliance components
COMMISSIONING
Following installation or any maintenance
operations, check appliance operation. In the event
of any malfunction, consult the next paragraph
"Troubleshooting".
ELECTRICAL APPLIANCES
Switch on the appliance as directed in the instructions
and reminders for use given in Chapter "INSTRUCTIONS
FOR USE" and check:
•
The current values of each phase.
•
The correct operation of the heating elements.
15. TROUBLESHOOTING
ELECTRIC FRYERS
The appliance does not heat.
Possible causes:
•
Temperature thermostat defective.
•
Heating elements defective.
•
Safety thermostat tripped.
Heating cannot be adjusted.
Possible causes:
•
Temperature thermostat defective.
Instructions for maintenance
16. REPLACING COMPONENTS
REMINDERS FOR REPLACING COMPONENTS
•
Disconnect the appliance electrical power supply, if
present, before proceeding with any operation.
•
After replacing an electrical system component, check it
is correctly wired.
Replacing the oil drain tap
•
Remove the control panel.
•
emove the bottom of the appliance.
•
Remove and replace the component.
•
Re-assemble all parts. For assembly, proceed in
reverse order.
ELECTRIC FRYERS
Replacing the working thermostat and safety
thermostat.
•
Drain off all the oil from the well
•
Remove the control panel.
•
Unscrew the locking nut on the heating element flange.
•
Release the thermostat bulb to be replaced; it is
secured between the heating elements with a flexible
clip.
•
Disconnect the electrical connections to other devices.
•
Remove and replace the component.
•
Change the sensor/bulb sealing O-ring in the well.
•
Re-assemble all parts. For assembly, proceed in
reverse order.
Replacing the heating element.
•
Drain off all the oil from the well
•
Remove the control panel and the cover protecting the
wiring of the heating elements.
•
Release the thermostat bulbs secured between the
heating elements.
•
Disconnect the electrical connections to other devices.
•
Remove and replace the component.
•
Re-assemble all parts. For assembly, proceed in
reverse order.
17. CLEANING THE INTERIOR
•
Check the condition of the inside of the appliance.
•
Remove any built-up dirt.
18. MAIN COMPONENTS
ELECTRIC FRYERS
•
Safety thermostat
•
Working thermostat
•
Heating element.
25