7.3
Troubleshooting
Flashing pattern and user interface
Flashing
Lights up / switched on
Switched off
Flashing alternately
Flashing simultaneously
LED
Green
Orange
Red (2)
(1)
(3)
Operating states
Alarm statuses / errors
*) If the error occurs again, inform Customer Service.
**) The battery monitoring is only active if a battery was connected on putting into service.
30 / 112
Acoustic
Description
signal
-
Power outage
-
Ready for operation
Rotating field or phase error
Motor protection - motor pro-
tection switch has triggered
Motor protection - motor
current too high due to
defective or blocked pump
Motor protection - maximum
operating cycles exceeded
Temperature fault (winding tem-
perature switch has triggered)
Temperature fault
(bridge TF1/TF2 missing)
Relay operating cycles exceeded
Relay error (relay does not switch)
(1)
Power LED (green)
(2)
Alarm LED (red)
(3)
Manual opera-
tion LED (orange)
Restore the mains voltage
Carry out pump maintenance.
Acknowledge alarm, replace
control unit if occurs regularly.
Self-resetting when the motor cools
down. Acknowledge fault message
with alarm button, please contact
Customer Service if further temper-
ature fault messages are issued.
Power contactor has carried out
more than 100,000 operating cycles.
Have the control unit replaced
during the next maintenance.
Switch off the voltage sup-
replaced by Customer Service.
(4)
Alarm button
(5)
Manual oper-
ation button
Measure
-
Connect the rotating
field/phases correctly.
Switch motor protec-
tion switch on again.
Set bridge.
ply of the control unit and
have the power contactor
016-189_01