7.0 PRODUCT DESCRIPTION ATM-3

ATM-3 is an aid for use in normal maintenance and
installation procedures and allows the realignment of
misaligned flanges within a 3 ton (27kN) physical
capacity.
It may be used to assist in the
replacement of ring and other type joints.
The use of these instructions will promote the safe
use and maximum service life of ATM-3.
It is recommended that all sections of this instruction
book be read prior to using the equipment.
7.1 APPLICATIONS
Alignment tools (ATM-3 as well as ATM-1) can be
used for: Flange change outs, repair of pipe lines,
replacing bolts, gasket and seals and for aligning
parts for fabricating.
Fig. 8
Torque Wrench
.
.
Reversible Lift
Hook

8.0 SAFETY INFORMATION

IMPORTANT: In all installations the site safety
requirements must be adhered to and that safety of
the operator and, when present, any assisting
personnel is of paramount importance along with the
safety of others including, when present, the general
public.
These instructions are only to cover the safe
operation of ATM-3 during a normal maintenance /
installation operation. All other safety aspects must
be controlled by the operation supervisor.
CAUTION: ATM-3 must not be attached to
pressure vessel nozzles.
.
.
. .
.
.
SERIAL No: 0300
.
Pin
CAUTION: ATM-3 must not be attached to
a joint prior to misalignment.
9.0 LIST OF EQUIPMENT
The carrying case for ATM-3 has cut outs, for each
component. A rapid check that all parts are present
is possible.
An illustrated parts list is on page 11.
10.0 FUNCTION OF ATM-3
Fig. 9
Extend
Wing
Swivel
The ATM-3 should be secured to the lower of the two
flanges by fully inserting the lift hook into the bolt hole
which is parallel with the bolt hole on the opposite
flange, this is where the misalignment is at its worst
point. The drop leg should be released onto the pipe
while the tool is held up level in the bolt hole.
Pull out on wing release clip to allow the wing to be
extended to the desired distance.
NOTE: The lift hook is reversible for varying flange
sizes.
The swivel at the base of the screw bolt should
always rest fully on the circumference of the
opposite flange.
By tightening the screw bolt down on the flange
circumference ATM-3 will react by lifting the lower
flange into line and the bolts can be inserted.
11.0 MISALIGNMENT DETERMINATION
PROCEDURE
• The ATM-3 MUST NOT be attached to a flanged
joint prior to the misalignment determination
procedure being carried out.
• Every second bolt should be loosened and
removed around the flange. Continue with this
procedure. Misalignment may not occur until only
a few bolts remain. At this point the direction of
any misalignment should become obvious.
5
Screw
Wing
Bolt
Release
Clip
Drop
.
.
Leg
.
. .
.
.