Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Powering The Fixture; Rigging The Fixture - JB-Lighting VaryLED Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

weight:
Power connection:
Power consumtion:
max. amb. temp.:

2. Installation

2.1 Powering the fixture

WARNING: To ensure propper installation of the plug consult
!
Install a 3-prong grounding type plug that fits your supply.
Connected load: voltage 230 V, frequency 50 Hz

2.2 Rigging the fixture

WARNING: Keep fixtures at least 0,5 m away from inflamable articles!
!
The VaryLED 3*84 can either be placed on the floor or hung on a trussing system
in a vertical or horizontal way. When placing the unit on the floor make sure that it
stands on rigid ground, because the air inlets in the base must not be covered with
anything!
To mount the unit on a trussing system use the original JB-lighting omega brackets
with Camloc-connectors. The Camlocs must snap in to be locked propperly.
Always attach a safety cable to secure the unit.
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Telefon +49 (0)7304-9617-0
12 kg
230 V, 50-60 Hz
330VA
40°C
a qualified technician!
brown
live
blue
neutral
yellow/green ground
Always use a safety cable attached to the base!
"L"
"N"
head
Yoke
control panel
ring eye for safety cable
attachement
fuse
power supply
XLR-connector
base
omega bracket
camloc connector
21

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Varyled 384

Inhaltsverzeichnis