2. Installation
2.1 Installing or changing the lamp
WARNING: Disconnect fixture from mains, and allow
!
Light source: OSRAM HMI 575 GS
Position head in horizontal position. Hinge no. 1 must be on the
upper side of the head. Turn screws no. 5 1/2 turn left and remove
plastic lid.
Loosen knurled head screw no. 3 and open the lampcover.
Insert the lamp into the lamp holder. The nipple of the lamp
must face the top lid of the head. (See sketch).
If changing the lamp, remove old lamp from
lamp socket. Hold the new lamp only by its
ceramic base. Never touch the glass bulb.
2.2 Powering the fixture
WARNING: To ensure propper installation of the plug consult
!
Install a 3-prong gounding type plug that fits your supply
Connected load: voltage 230V, frequency 50Hz.
hot lamp to cool down for at least 30 minutes!
nipple
a qualified technician!
brown
live
blue
neutral
yellow/green ground
"L"
"N"
2
1
3
21