Protect against unauthorized access and children.
When starting-up, comply with the daily checks before start-up.
7.2.

Warehousing

Warehousing means storing the power generator in an inoperable state without a time limit. To do
that, preservation work and inspections are required at regular intervals. Warehousing under weath-
er-protected conditions is described below. To warehouse under different conditions, consult our ser-
vice representatives.
Perform all necessary maintenance and cleaning work as described in the Maintenance chapter.
Place a desiccant bag inside the tank.
Do an oil change.
Remove the spark plug.
Fill 10cc engine oil through the opening into the cylinder.
Turn the engine with the recoil starter several times slowly through.
Screw the spark plug back in.
Seal the intake of the air filter and the exhaust outlet airtight.
Remove the battery.
Store the battery in accordance with the standards and check the charge status every 2 months.
Protect all surfaces with a preservative.
Protect power generators from dust and moisture.
Storage temperature between -20 ° C to + 70 ° C.
Protect against unauthorized access and children.
When retrieving, follow the instructions on preparation for commissioning and do the daily
checks before start-up..
These provisions are to be repeated at regular intervals, but at least after 2 years.