PERFORMANCE DESCRIPTION OF THE POWER GENERATOR

3.1.

Definition of the device class

The GEKO/EISEMANN power generator is part of the device class of power generating units with an
internal combustion engine and an Asynchronous generator and is designed for the generation of
400/230 V, 50 Hz in the commercial and private environment. The input supply feed comes from a
portable distribution network.
The power generator is characterized particularly by its robust design and the IP 54 protection class.
The power generator with asynchronous generator has a special starting booster for heavy-starting
consumers and low distortion for operating electronic consumers.
3.2.

Intended use

The power generator produces electrical energy in the context of stand-by operation for feed-
ing into a portable distribution system.
Connect electric consumers only up to the total power specified on the rating plate. You will
find the rating plate of the left-hand side below the power generator control box.
Please note the specifications for voltage and frequency.
Note the start/inrush current on inductive consumers.
The loop impedance as the sum of all connected lines may not be greater than 1.5 Ω as per ISO
8528-8. That results in cable lengths of up to 60 meters with a cable cross section of 1.5 mm²
and up to maximum 100 m with a cable cross-section of 2.5 mm². Use only approved, standard-
ized extension cords.
Electronically controlled devices can be sensitive to over- or under-voltage. These voltage fluc-
tuations can cause interference or damage to these devices. Consult the manufacturer to find
out if its device is suitable for power generator operation.
Operate the power generator only outdoors. Comply with the minimum clearances stated in
this document. The fresh air and exhaust air openings must be free.
Note the selected mains configuration. If your power generator is provided with a residual cur-
rent device (RCD), it must be properly grounded before commissioning/starting.
To ensure proper use, read and observe the operating instructions for the power generator and
the motor drive.
Comply with the requirements for servicing and maintenance.