Herunterladen Inhalt Inhalt Diese Seite drucken

Attachment And Operation; Electrical Connection - Parkside PKO 500 A2 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Before you connect the equipment to the mains supply make
sure that the data on the rating plate are identical to the mains
data.
• Prior to initial commissioning, remove the transport plug (A)
and fill the crank housing with oil as described in item 9.5.
• Check the equipment for damage which may have occurred
in transit. Report any damage immediately to the transport
company which was used to deliver the compressor.
• Install the compressor near the point of consumption.
• Avoid long air lines and supply lines (extension cables).
• Make sure that the intake air is dry and dustfree.
• Do not install the compressor in a damp or wet room.
• The compressor may only be used in suitable rooms (with
good ventilation and an ambient temperature from +5 °C
to 40 °C). There must be no dust, acids, vapors, explosive
gases or inflammable gases in the room.
• The compressor is designed to be used in dry rooms. It is
prohibited to use the compressor in areas where work is con-
ducted with sprayed water.
• The oil level in the compressor pump has to be checked be-
fore putting the equipment into operation.

9. Attachment and operation

m Important!
You must fully assemble the appliance before us-
ing it for the first time!
You will require the following tools for assembly and installa-
tion:
1x Open-end spanner 13mm
(not included)
9.1 Fitting the wheels (Fig. 4)
• Fit the supplied wheels as shown.
9.2 Fitting the supporting feet (Fig. 5)
• Fit the supplied supporting foot as shown.
9.3 Fitting the transport handle(Fig. 6)
• Fit the supplied transport handle as shown.
9.4 Fitting the air filter (Fig. 7, 8)
• Remove the transportation stop (B) and screw the air filter
(15) to the equipment.
9.5 Changing the transportation cover (A)
(Fig. 9, 10)
• Remove the transport lid (A) of the oil filling opening (20).
• Fill the included compressor oil into the crank housing and
insert the included oil sealing plug (16) into the oil filling
opening (20).
9.6 Mains connection
• The compressor is equipped with a mains cable with shock-
proof plug. This can be connected to any 220 - 240 V∼ 50
Hz shock-proof socket.
• Before you use the machine, make sure that the mains volt-
age is the same as the operating voltage (see the rating
plate).
16
GB/IE
• Long supply cables, extensions, cable reels etc. cause a drop
in voltage and can impede motor start-up.
• At low temperatures below +5°C, sluggishness may make
starting difficult or impossible.
9.7 ON/OFF switch (Fig. 2)
• Pull the ON/OFF switch (17) upwards to switch on the com-
pressor. To switch off the compressor, press the ON/OFF
switch down.
9.8 Setting the pressure (Fig. 1, 3)
• Use the pressure regulator (5) to set the pressure on the pres-
sure gauge (4).
• The set pressure can be drawn from the quick lock coupling
(3).
• The vessel pressure can be read off the pressure gauge (6).
• The vessel pressure is drawn from the quick lock coupling
(7).
9.9 Setting the pressure switch (Fig. 1)
• The pressure switch (2) is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar.
9.10 Fitting the compressed air hose (Fig. 1, 3)
• Connect the nipple (H) on the compressed air hose (14) to
one of the quick release couplings (3, 7). Then attach the
compressed air tool to the quick-release coupling (I) on the
compressed air hose (14).
9.11 Overload switch (Fig. 14)
The motor is fitted with an overload switch (24). If the compres-
sor overloads, the overload switch switches off the equipment
automatically to protect the compressor from overheating. If
the overload switch triggers, switch off the compressor using
the ON/ OFF switch (17) and wait until the compressor cools
down. Then press the overload switch (24) and restart the com-
pressor.

10. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the extension
cable used must also comply with these regula-
tions.
Important information
In the event of an overloading the motor will switch itself off. Af-
ter a cool-down period (time varies) the motor can be switched
back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often dam-
aged.
This may have the following causes:
• Passage points, where connection cables are passed through
windows or doors.
• Kinks where the connection cable has been improperly fas-
tened or routed.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ian 327366_2001

Inhaltsverzeichnis