6. Technical data

Mains connection
Motor rating W
Operating mode
Compressor speed
Pressure vessel capacity (in liters)
Operating pressure
Theoretical intake capacity (l/min)
sound power level L
PA
sound power level L
WA
uncertainty K
PA/WA
Protection type
Weight of the unit in kg
Oil (15W 40) l
Max. altitude
(above mean sea level)
The noise emission values were measured in accordance
with EN ISO 3744:2010.
Wear hearing protection.
The effects of noise can cause a loss of hearing.

7. Before starting the equipment

Before you connect the equipment to the mains supply make
sure that the data on the rating plate are identical to the
mains data.
• Prior to initial commissioning, remove the transport plug
(A) and fill the crank housing with oil as described in item
8.5.
• Check the equipment for damage which may have oc-
curred in transit. Report any damage immediately to the
transport company which was used to deliver the com-
pressor.
• Install the compressor near the point of consumption.
• Avoid long air lines and supply lines (extension cables).
• Make sure that the intake air is dry and dustfree.
• Do not install the compressor in a damp or wet room.
• The compressor may only be used in suitable rooms (with
good ventilation and an ambient temperature from +5 °C
to 40 °C). There must be no dust, acids, vapors, explosive
gases or inflammable gases in the room.
• The compressor is designed to be used in dry rooms. It is
prohibited to use the compressor in areas where work is
conducted with sprayed water.
• The oil level in the compressor pump has to be checked
before putting the equipment into operation.

8. Attachment and operation

m Important!
You must fully assemble the appliance before using it
for the first time!
38
GB/MT
230 V ~ 50Hz
1800
S1
2850 min
-1
approx. 50
approx. 10 bar
approx. 260
74.3 dB(A)
94.3 dB(A)
2.37 dB
IP20
approx. 34
approx. 0.25
1000 m
You will require the following tools for assembly and installation:
2x Open-end spanner 13mm
(not included)
8.1 Fitting the wheels (Fig. 4)
• Fit the supplied wheels as shown.
8.2 Fitting the supporting feet (Fig. 5)
• Fit the supplied supporting foot as shown.
8.3 Fitting the transport handle(Fig. 6)
• Fit the supplied transport handle as shown.
8.4 Fitting the air filter (Fig. 7, 8)
• Remove the transportation stop (B) and screw the air filter
(15) to the equipment.
8.5 Changing the transportation cover (A) (Fig. 9, 10)
• Remove the transport lid (A) of the oil filling opening (20).
• Fill the included compressor oil into the crank housing
and insert the included oil sealing plug (16) into the oil
filling opening (20).
8.6 Mains connection
• The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any 220 -
240 V~ 50 Hz shock-proof socket.
• Before you use the machine, make sure that the mains voltage
is the same as the operating voltage (see the rating plate).
• Long supply cables, extensions, cable reels etc. cause a
drop in voltage and can impede motor start-up.
• At low temperatures below +5°C, sluggishness may make
starting difficult or impossible.
8.7 ON/OFF switch (Fig. 2)
• Pull the ON/OFF switch (17) upwards to switch on the
compressor. To switch off the compressor, press the ON/
OFF switch down.
8.8 Setting the pressure (Fig. 1, 3)
• Use the pressure regulator (5) to set the pressure on the
pressure gauge (4).
• The set pressure can be drawn from the quick lock cou-
pling (3).
• The vessel pressure can be read off the pressure gauge (6).
• The vessel pressure is drawn from the quick lock cou-
pling (7).
8.9 Setting the pressure switch (Fig. 1)
• The pressure switch (2) is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar.
8.10 Fitting the compressed air hose (Fig. 1, 3)
• Connect the nipple (H) on the compressed air hose to
one of the quick release couplings (3, 7). Then attach the
compressed air tool to the quick-release coupling (I) on
the compressed air hose.