5.1.5 Water connection

Take care, that a drinking water connection is in the vicinity of the device.
Before connecting the device enable to flow off sufficient amount of water, in order
to remove any residual substances that are in the pipeline, so they do not reach the
solenoid valves.
It is necessary to install, between the water
network and the device a shut-off valve and a
mechanical filter (Figure on the right).
The convection oven has an input G3/4 '' with
filter on back side of the device on the area
marked with a label.
Withn the scope of delivery it is contained a water
pressure hose with length of 2 m with G3/4 ''
connection and a check valve, as is required by
the applicable regulations.
CAUTION!
In order to connect the convection oven to
the water network only the supplied water
pressure hose may be used! Do not use any
other hoses.
The incoming water must have a pressure value
between 150 kPa (1.5 bar) and 200 kPa (2 bar)
and a temperature below 30 ° C. If the input
pressure value is higher than 200 kPa (2 bar), it
must be installed a pressure reducer which is
calibrated to 200 kPa (2 bar).
For proper functioning and in order to avoid lime
deposits in the cooking space, the water must
have a maximum hardness of 5 ° dH. A suitable
water softener must be preinstalled at higher
values.