Installation example
Example 1 (recommended): Installation when a stop surface of the scale and the scale head is
Scale installation accuracy is improved when a stop surface is made. Th is also simplifi es reinstallation of
the scale.
1. Check and adjust the scale bracket's parallelism with respect to the machine guide, and then secure in
place.
As shown in the fi gure, adjust the parallelism over the entire bracket length even when making a
diff erence in levels on the scale installation surface.
Scale bracket
2. Check and adjust the height and parallelism of the scale head bracket, and then secure in place.
8
(E)
made with the bracket.
0.05 MG
Or
Fig. 3-5
0.05 MG
Scale head bracket
Fig. 3-6
0.05 MG
78
± 0.3
Scale head bracket
Scale bracket
78
± 0.3
Unit: mm
Unit: mm