Herunterladen Inhalt Inhalt Diese Seite drucken

PeakTech 4960 Bedienungsanleitung Seite 42

Ir-thermometer
Vorschau ausblenden Andere Handbücher für 4960:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

This is a result of the cooling process which must take place for
the IR sensor.
5. Non-Contact IR Measurement Operation
5.1. Power ON/OFF
1. Press the ON/HOLD button to take a reading. Read the
measured temperature on the LCD.
2. The meter powers OFF automatically approximately 7
seconds after the ON/HOLD button is released.
5.2. Selecting Temperature Units (°C/°F)
1. Select temperature units (degrees °C or °F) by first pressing
the ON/HOLD button and then pressing the ▲ or ▼ button.
The unit will be seen on the LCD
5.3. Data Hold
This meter automatically holds the last temperature reading on
the LCD for 7 seconds after the ON/HOLD button is released.
No extra button presses are necessary to freeze the displayed
reading.
5.4. Backlite LCD
Select backlite by first pressing the ON/HOLD button and then
pressing the LASER/BACKLIGHT-button. Press the backlight
button again to turn the backlight OFF.
5.5. Laser Pointer
1. To
turn
LASER/BACKLIGHT-button after pressing the ON/HOLD
button.
2. Press the LASER/BACKLIGHT-button again to turn the
laser OFF.
the
laser
-41-
pointer
ON,