Herunterladen Inhalt Inhalt Diese Seite drucken

Connection; Battery Test - Bosch BAT 171 Betriebsanleitung

Batterietester
Vorschau ausblenden Andere Handbücher für BAT 171:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
18 | BAT 171 | Operation
5.4

Connection

!
Please study Section 4: "Points to be noted and
observed when testing starter batteries".
i
The battery test is preferably to be performed at the
battery posts. If the battery is not accessible, the
battery tests can also be conducted at the jumper
post. A lower power value may then however be
displayed.
1. Connect the red clip of the battery connecting cable
to the positive post (+) of the 12 V battery.
2. Connect the black clip of the battery connecting
cable to the negative post (-) of the 12 V battery.
"
Depending on the chosen setting (refer to
Section 5.3.1), either the measured battery voltage
is displayed or the battery test is started.
i
Move the battery clips back and forth to check for
proper connection. The two clips must be firmly
attached on both sides before starting the test.
i
In the event of poor contact, the message "CHECK
CONNECTION" or "WIGGLE CLAMPS" is displayed. In
this case, clean the battery posts and re-connect the
battery clips.
i
Observe the key commands available in the
button bar.
i
After switching off the BAT 171, the last parameter
settings made are retained until the unit is next
switched on.
|
1 689 989 061
2009-10-16
5.5

Battery test

Select values or specifications with
Store values or parameters and continue with
Return to the last selection with 
i
Hold
and
to scroll more rapidly through the
values.
i
Refer to Section 5.7 for information on additional
prompts during the battery test.
1. BATTERY TYPE:
Select NORMAL or VRLA (Valve Regulated Lead Acid,
AGM- or Gel-Batterie) and press
2. BATTERY STANDARD:
Select the standardization system of the battery
and press
.
i
Not all standardization systems are available for
every application.
Type
Description
JIS
Japanese Industrial Standard;
combination of letters and numbers
on the battery.
EN
European standard
DIN
German industrial standard
SAE
Society of Automotive Engineers;
the European designation for CCA
IEC
International Electrotechnical
Commission
CCA
Cold Cranking Amps
3. BATTERY RATING (depending on type selected):
Select the characteristic value and press
? The battery test (TESTING) is started.
"
After a few seconds, the battery status result and
the measured voltage are displayed. The BAT 171
also indicates the standardization system selected
and the characteristic value.
GOOD BATTERY
VOLTAGE TOO
12.40V
MEASURED
361 EN(A)
RATING
380 EN(A)
and
.
.
.
.
Range
26A17 - 245H52
100 – 2000
100 – 1200
100 – 2000
100 – 1200
100 – 2000
.
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis