Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Preparation; Switch-On; Main Menu "Menu - Bosch BAT 171 Betriebsanleitung

Batterietester
Vorschau ausblenden Andere Handbücher für BAT 171:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.

Operation

The BAT 171 is supplied with power from the 12 V
battery to be tested or from the internal batteries. The
BAT 171 is provided with protection against incorrect
polarity, overvoltage and overheating.
5.1

Preparation

Before connecting the BAT 171, use a wire brush and a
mixture of natron and water to clean the battery posts.
For testing 12 V batteries with side posts, attach and
secure post adapters.
!
Never use steel screws as measurement points. The
test results may be biased if no post adapters are
attached or use is made of worn or contaminated
post adapters. To prevent damage, the post adapters
are not to be tightened by more than a quarter turn
using a wrench.
i
When testing a 12 V battery in a vehicle, switch off
all additional loads, remove the ignition key and
close the doors.
5.2

Switch-on

Connect the BAT 171 by way of battery clips to
a 12 V battery.
"
The software version installed is displayed for two
seconds.
"
Depending on the chosen setting (refer to
Section 5.3.1), either the measured battery
voltage is displayed or the battery test is started
immediately.
i
The settings in the main menu "MENU" can also be
altered without connecting the BAT 171 to a 12 V
battery. In this case, switch on the BAT 171 by
pressing the <Menu> key (power supply via internal AA
batteries).
Robert Bosch GmbH
Operation | BAT 171 | 17
5.3

Main menu "MENU"

5.3.1

Menu items

1. Call up the main menu with
? "MENU" is displayed.
2. Select a menu item with
3. Continue with
.
i
Use
to return to the main menu without storing.
Menu item
Function / notes
VIEW / PRINT
Display of last test result.
Use
EXPORT DATA.
No function
PERFORM TEST
Start of battery test.
LANGUAGE
Language selection.
SET ADRESS
Entry of the address to appear on the
print-out.
SET TIME
Selection of 24-hour or AM/PM time
format and setting of time.
SET DATE
Selection of date format and setting of
correct date.
COUNTER
Display of battery and system tests
according to result or deletion of results
(CLEAR COUNTERS.).
CONTRAST
Alteration of display contrast setting with
and
TEMP. UNITS
Selection of unit of temperature (degrees
Fahrenheit or centigrade).
VOLTMETER
ON: After switch-on, the battery voltage is
measured automatically.
OFF: After switch-on, the battery test
is started.
If the setting is altered from "OFF" to
"ON", the battery voltage is displayed and
the battery test then started.
5.3.2

Entering address

i
6 lines are provided with 21 characters each. The
specified standard text must be overwritten in full.
Use E to save the entries at the end of the line.
1. Call up the main menu with
? "MENU" is displayed.
2. Select the menu item "SET ADDRESS" with
3. Continue with
.
4. Select the line with
5. Continue with
.
6. Select the character with
7. Continue with
.
? The cursor moves one space to the right.
8. Repeat the procedure as far as the end of the line.
9. To enter further lines: Repeat steps 4 – 8.
BAT 171 | 17
| 17
.
and
.
to print the result.
.
.
and
and
.
and
.
|
1 689 989 061
2009-10-16
en
.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis