Arranging ceramic "logs" and embers layer

NB!
It is very important that you follow this when positioning ceramic "logs" and the embers layer in
the fireplace. Failure to carry this out correctly will result in a flame profile that is less than optimal.
When arranging ceramic "logs" and the embers layer in the combustion chamber, it is important that
they do not cover the pilot flame and its thermocouple, and ember material must not be placed under
the pilot guard. Both thermocouples must be kept free of the embers layer.
Do not cover the holes in the main burner (shown by the red circles).
When commissioning or servicing the fireplace it must be ensured that the cross-ignition (from the
pilot flame to the main burner) functions, and that ignition occurs easily with the secondary burners.
46 - GB
CERAMIC "LOGS" AND THE EMBERS LAYER
Pilot flame
Second thermocouple for the main burner