Technical Data; Mode Of Operation; Type Key; Scope Of Delivery - Wilo DrainLift WS 40 Einbau- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für DrainLift WS 40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.1.1

Technical data

4.1.2
Dimensions
Fig. 2: Dimension drawings
4.1.3
Materials
4.2

Mode of operation

4.3

Type key

4.4

Scope of delivery

Installation and operating instructions Wilo-DrainLift WS 40/50
Product description
Pipework
ƒ
Discharge pipe with flange connection on the pump side
ƒ
Gate valve
ƒ
Surface coupling
ƒ
Non-return ball valve (integrated in the surface coupling)
ƒ
Vessel volume: 255 l/67 US.liq.gal. (WS...E)/400 l/105 US.liq.gal. (WS...D)
ƒ
Maximum pressure in the pressure pipe: 6 bar (87 psi)
ƒ
Pressure connection: R 1½ (WS 40), R 2 (WS 50)
ƒ
Inlet connection: DN 100/150/200
ƒ
Aeration and ventilation connection: 75 mm (3 in)
ƒ
Cable pipe for ground installation: 63 mm (2.5 in)
ƒ
Threaded cable glands for building installation:
- WS...E: 1x M25 + 2x M16
- WS...D: 2x M16 + 2x M25
ƒ
Fluid temperature: 3 ... 40 °C (37 ... 104 °F)
ƒ
Max. ambient temperature: 3 ... 40 °C (37 ... 104 °F)
ƒ
Max. ground water level: 500 mm
Refer to the dimension drawing for the dimensions:
1
DrainLift WS 40E
2
DrainLift WS 40D
3
DrainLift WS 50E
4
DrainLift WS 50D
When the pump chamber extension is installed, the dimensions change as follows:
Pump chamber extension height
Pump chamber total height
Max. vessel volume
Max. ground water level
ƒ
Pump chamber: PE
ƒ
Pipework: 1.4404 (AISI 316L)
ƒ
Surface coupling: PUR
ƒ
Non-return valve: PUR
ƒ
Gate valve: Red brass
The sewage produced is channelled into the pump chamber via the inlet, where it col-
lects. When the water level reaches the switch-on level, the pump is switched on. The
collected sewage is pumped into the on-site pressure pipe via the discharge pipe. When
the switch-off level is reached, the pump is deactivated.
Pump chambers with two pumps operate according to the base load and peak load
principle. The pumps are switched on depending on the fill level. Depending on the
switchgear, pump cycling is carried out after every pumping procedure. If one pump
malfunctions, the other pump is automatically used.
Example: DrainLift WS 40E
Product family
DrainLift
WS
Pump chamber
40
Size
E
Chamber design:
ƒ
E = single pump chamber
ƒ
D = double pump chamber
ƒ
Plastic chamber with installed pipework
Pipework with gate valve and surface coupling with integrated non-return valve
ƒ
Chamber cover with gasket
ƒ
HT double socket 50 mm (2 in) for evacuation connection
ƒ
Inlet set with hole saw 124 mm (5 in)and gasket DN 100
DrainLift WS ... E
DrainLift WS ... D
300 mm (12 in)
300 mm (12 in)
1342 mm (53 in)
1342 mm (53 in)
325 l (86 US.liq.gal)
470 l (124 US.liq.gal)
1000 mm (39 in)
500 mm (19.5 in)