Divider Incremental
Encoder Output
ASM/SSM-Selection
Reverse Direction of Travel
ASM-Rated Motor Power
8. Parameter Description
With LF.3 you can preselect a divider for the signals of the incremental
encoder output (X5). The adjusted value is valid after a power-on-
reset.
Unit:
Value range:
Factory setting:
No divider possible with resolver connection (1 : 1)!
With parameter LF. 4 you can select, if it is an asynchronous motor
or a three-phase synchronous servo motor. LF.4 releases the
adjusted motor parameter for the selected motor and does
independently a Power-On-Reset.
Unit:
Value range:
Factory setting:
Adjustment value:
With LF. 5 travel direction can be changed.
LF. 5
X2.3
OFF
1
OFF
0
ON
1
ON
0
Unit:
Value range:
Factory setting:
Adjustment value:
Unit:
Value range:
Factory setting:
Adjustment value:
1
1...128
1
1
0:ASM / 1:SSM
0:ASM
in accordance with type of the motor
X2.4
Speed setpoint
0
n_set > 0
1
n_set < 0
0
n_set < 0
1
n_set > 0
1
0:off / 1:on
0:off
in accordance with the direction of travel
kilowatt
0,00...75,00 kW
4,00 kW
in accordance with the motor name plate
ANTRIEBSTECHNIK
GB
Inverter status
Fxxx
rxxx
rxxx
Fxxx