8. Parameter Description
Actual Speed
Actual Lft Speed
GB
ASM - Rated Motor Torque
Positioning Drive
Error State
Inverter State
GB 44
The value shows the real speed in rpm, led from the impulses of
the incremental encoder .
Display of the speed in m/s; only when the encoder is connected.
Using the rating plate data the inverter determines the motor rated
torque in the rated point. Unit Nm.
Unit:
Factory setting:
Display of the positioning drive in cm, after the drive has finnished.
The parameter shows the fault indications that occur during the
starting process and continuous operation.
Display Significance
StOP
no setpoint selection
S.Co
setpoint selection without contactor control
S.IO
setpoint selection without control release
S.nC
no current flows on the output side, check the wiring
between motor and inverter
run
starting procedure is completed
See parameter LF.99 for more information about other fault indications.
a) Running Messages
Display Value Significance
bbl
76
base-block-time runs out, power modules are blocked
for 3s (always when control release is cleared)
Facc
64
forward acceleration
Fcon
66
forward constant running
FdEc
65
forward deceleration
nOP
0
no Operation, terminal X2.1 is not set
LS
70
low speed, control release is switched but no
direction of rotation is adjusted, modulation disabled
rAcc
67
reverse acceleration
r Con
69
reverse constant running
rdEc
68
reverse deceleration
Newton meter
26,5 Nm