Verfügbare Sprachen

8.
DATE/TIME
9.
PROGRAM. ON/OFF
10.
ENERGY SAVING
Functions that can "ONLY" be accessed from the
TECHNICIAN mode.
This operation may ONLY be performed
by a Specialist Technician.
Adjustments made by Unqualified
Technicians or other people may render
the Guarantee null and void.
Additional functions that can be accessed from the
TECHNICIAN mode are:
11.
PREINFUSION
12.
TAMPING
13.
GROUNDS NUMBER
14.
MILK CLEAN WARN.
15.
CLEAN ALARM
16.
SHUT DOWN CLEAN
17.
GROUP SETTING
18.
GRINDER SETTING
19.
COFFEE TEMP.
20.
STEAM TEMP.
21.
PASSWORD
22.
SMART CARD
23.
WATER FILTER L
24.
DE-SCALE
7.2
Entering the programming function gives access to
all of the USER and TECHNICIAN mode functions.
For accessing the programming sites proceed as
follows:
NOTE: Can be performed with machine on.
• Insert the key into the appropriate lock.
• Turn the control panel hatch key counter-clock-
wise.
• Open the control panel hatch; the display will read:
• Press the ENTER key, close the front panel, the
display will read:
• Once the ejection cycle is over, the unit will enter
resting phase position and the display will show
the first item on the programming menu:
52
Downloaded from
www.Manualslib.com
PROGRAMMING
manuals search engine

KEY FUNCTIONS

 :
Scrolling function list Programmable and/or
decreasing / increasing values.
ENTER : To enter menus/ submenus and confirming data.
RESET : Moving back to preceding level. e confirming
data
7.3
EXITING
PROGRAMMING
To exit programming sites, proceed as follows:
NOTE: Can be performed with machine on and
from any of the visualized functions.
• Insert the key into the appropriate lock.
• Turn the control panel hatch key counter-clock-
wise.
• Open the control panel hatch; the display will
read:
• Close the front panel and turn the key clockwise.
The display will read:
To switch the machine on definitively, press the
"ENTER" key:
• Alternatively, scroll through all the functions using
the  key until the display reads:
7.4
PROGRAMMING CYCLE
USER MODE
1.
LANGUAGE
Press the ENTER key to access the sub-
menu.
This sets the language for operator-machine
interface, as shown on the display.
Press the  keys to select the required lan-
UK